Electromagnetic Flowmeter
MagProbe 6450
Insertion Type
Introduction
Electromagnetic Flow measurement has been in use around the world for 50 years and more, as witnessed by the popularity of these meters that continues unabated in virtually all sectors of industry. Electromagnetic Flowmeters can be used to measure all electrically conductive liquids (> 5 µS/cm) with or without solids, e.g. water, wastewater, sludge, slurries, pastes, acids, alkalis, juices, fruit pulp, etc.
Insertion Type Electromagnetic Flowmeter is suitable for the most demanding applications. They are based on Faraday’s law of Electromagnetic Induction. The meter features sensor tube and ball valve assembly.
Salient Features
Based on Faraday’s law of electromagnetic induction
Coil assembly in hermetically sealed welded construction
Field interchangeable electronics
Absolute zero stability and noise elimination due pulsed DC excitation
Flow tube sizes 100 mm to 600 mm
Integral or remote transmitter
High linearity due to characteristic magnetic field
High long-term stability and reliability
Applications
Chemical, petrochemical and process industries
Pharmaceutical industries
Fertilizers industries
Sugar, beverage industries
Salient Features
Based on Faraday’s law of electromagnetic induction
Coil assembly in hermetically sealed welded construction
Field interchangeable electronics
Absolute zero stability and noise elimination due pulsed DC excitation
Flow tube sizes 100 mm to 600 mm
Integral or remote transmitter
High linearity due to characteristic magnetic field
High long-term stability and reliability
Applications
Chemical, petrochemical and process industries
Pharmaceutical industries
Fertilizer industries
Sugar, beverage industries
Product Selection Guide
Parameters | Specifications |
---|---|
Nominal dia (mm) | > 100 |
Working pressure (kg/cm2) | 20 |
Working temperature | Up to 120°C |
Electrode material | SS 316L Std.* |
Sensor lining | NA |
Display version | Integral/Remote |
Measuring tube material | SS 316 Std.* |
Sensor housing material | NA |
End connection | NA |
Flange standard | NA |
Measuring range | 0.2 to 12 m/sec. Bidirectional |
Accuracy % of measured value | ±2% |
Repeatability | ±0.2% of Span |
Display | 2 line LCD |
Display units | All standard engineering units in m³, litre, gallon, ft³, imperial gallon |
Output | Std. 4 – 20 mA* |
Power supply | 12 – 60 V DC or 80 – 300 V AC/DC Solar powered |
Protection class for sensor | Std. IP 68 |
Protection class for transmitter | IP 67 |
Cable length for remote | Std. 10 m* |
Installation | Insertion type with use of isolating ball valve assembly on pipeline |