Electromagnetic Flowmeter
MagFlow 6410
Inline Mains Operated
Introduction
Electromagnetic flow measurement has been in use around the world for 50 years and more, as witnessed by the popularity of these meters that continues unabated in virtually all sectors of industry. Electromagnetic Flowmeters can be used to measure all electrically conductive liquids (> 20 µS/cm) with or without solids, e.g. water, wastewater, sludge, slurries, pastes, acids, alkalis, juices, fruit pulp, etc.
Adept MagFlow 6410 Full Bore Electromagnetic Flowmeter is suitable for the most demanding applications. It is based on Faraday’s law of Electromagnetic Induction. The meter features flanged construction and is available with choice of liner and electrode material. All meters consist of a sensor and a converter that may be mounted either integral to the sensor or remotely with a field mount kit. Adept Flowmeters are calibrated at our own Water Flow Calibration Facility. It uses the primary method of measuring the water flow by gravimetric principle. The facility is designed for calibration of flowmeters under controlled and stable flow conditions.
Salient Features
Based on Faraday’s law of electromagnetic induction
Coil assembly in hermetically sealed welded construction
High linearity due to characteristic magnetic field
High long-term stability and reliability
Flow tube sizes 10 mm to 3000 mm and above
Integral or remote transmitter
Field interchangeable electronics
Absolute zero stability and noise elimination due pulsed DC excitation
Applications
Chemical, petrochemical and process industries
Food and drug industries
Paper and pulp industries
Dredging industries
Fertilizers industries
Pharmaceutical industries
Sugar, beverage industries
Water and waste water management
Mining industries
Salient Features
Based on Faraday’s law of electromagnetic induction
Coil assembly in hermetically sealed welded construction
High linearity due to characteristic magnetic field
High long-term stability and reliability
Flow tube sizes 10 mm to 3000 mm and above
Integral or remote transmitter
Field interchangeable electronics
Absolute zero stability and noise elimination due pulsed DC excitation
Applications
Chemical, petrochemical and process industries
Food and drug industries
Paper and pulp industries
Dredging industries
Fertilizers industries
Pharmaceutical industries
Sugar, beverage industries
Water and waste water management
Mining industries
Product Selection Guide
Parameters | Specifications |
---|---|
Nominal dia (mm) | 10 to 3000 |
Working pressure (kg/cm2) | 10, 16, 25, 40 |
Working temperature | Integral PTFE – 120°C Remote PTFE – 180°C Others – 70°C |
Electrode material | SS 316L Std.* |
Sensor lining | Std. Rubber* |
Display version | Integral/Remote |
Measuring tube material | SS 304 Std.* |
Sensor housing material | Std. CS* |
End connection | Flange/Wafer/Tri-clamp/SMS |
Flange standard | ANSI 150* |
Measuring range | 0.2 to 12 m/sec. Bidirectional |
Accuracy % of measured value | ±O.5% (±O.2% consult factory) |
Repeatability | ±0.2% of Span |
Display | 2 line LCD |
Display units | All standard engineering units in m3, litre, gallon, ft3, imperial gallon |
Output | Std. 4 – 20 mA* |
Power supply | 12 – 60 V DC or 80 – 300 V AC/DC Solar powered |
Protection class for sensor | Std. IP 65 Option IP 67/IP 68 for flow tube in remote type |
Protection class for transmitter | IP 67 |
Cable length for remote | Std. 10 m* |
Installation | Inline flanged type |